タグ | VR | VM | 名称 | 概要 |
---|---|---|---|---|
(0022,0001) | US | 1 | Light Path Filter Pass-Through Wavelength | |
(0022,0002) | US | 2 | Light Path Filter Pass Band | |
(0022,0003) | US | 1 | Image Path Filter Pass-Through Wavelength | |
(0022,0004) | US | 2 | Image Path Filter Pass Band | |
(0022,0005) | CS | 1 | Patient Eye Movement Commanded | |
(0022,0006) | SQ | 1 | Patient Eye Movement Command Code Sequence | |
(0022,0007) | FL | 1 | Spherical Lens Power | |
(0022,0008) | FL | 1 | Cylinder Lens Power | |
(0022,0009) | FL | 1 | Cylinder Axis | |
(0022,000A) | FL | 1 | Emmetropic Magnification | |
(0022,000B) | FL | 1 | Intra Ocular Pressure | |
(0022,000C) | FL | 1 | Horizontal Field of View | |
(0022,000D) | CS | 1 | Pupil Dilated | |
(0022,000E) | FL | 1 | Degree of Dilation | |
(0022,0010) | FL | 1 | Stereo Baseline Angle | |
(0022,0011) | FL | 1 | Stereo Baseline Displacement | |
(0022,0012) | FL | 1 | Stereo Horizontal Pixel Offset | |
(0022,0013) | FL | 1 | Stereo Vertical Pixel Offset | |
(0022,0014) | FL | 1 | Stereo Rotation | |
(0022,0015) | SQ | 1 | Acquisition Device Type Code Sequence | |
(0022,0016) | SQ | 1 | Illumination Type Code Sequence | |
(0022,0017) | SQ | 1 | Light Path Filter Type Stack Code Sequence | |
(0022,0018) | SQ | 1 | Image Path Filter Type Stack Code Sequence | |
(0022,0019) | SQ | 1 | Lenses Code Sequence | |
(0022,001A) | SQ | 1 | Channel Description Code Sequence | |
(0022,001B) | SQ | 1 | Refractive State Sequence | |
(0022,001C) | SQ | 1 | Mydriatic Agent Code Sequence | |
(0022,001D) | SQ | 1 | Relative Image Position Code Sequence | |
(0022,001E) | FL | 1 | Camera Angle of View | |
(0022,0020) | SQ | 1 | Stereo Pairs Sequence | |
(0022,0021) | SQ | 1 | Left Image Sequence | |
(0022,0022) | SQ | 1 | Right Image Sequence | |
(0022,0030) | FL | 1 | Axial Length of the Eye | |
(0022,0031) | SQ | 1 | Ophthalmic Frame Location Sequence | |
(0022,0032) | FL | 2-2n | Reference Coordinates | |
(0022,0035) | FL | 1 | Depth Spatial Resolution | |
(0022,0036) | FL | 1 | Maximum Depth Distortion | |
(0022,0037) | FL | 1 | Along-scan Spatial Resolution | |
(0022,0038) | FL | 1 | Maximum Along-scan Distortion | |
(0022,0039) | CS | 1 | Ophthalmic Image Orientation | |
(0022,0041) | FL | 1 | Depth of Transverse Image | |
(0022,0042) | SQ | 1 | Mydriatic Agent Concentration Units Sequence | |
(0022,0048) | FL | 1 | Across-scan Spatial Resolution | |
(0022,0049) | FL | 1 | Maximum Across-scan Distortion | |
(0022,004E) | DS | 1 | Mydriatic Agent Concentration | |
(0022,0055) | FL | 1 | Illumination Wave Length | |
(0022,0056) | FL | 1 | Illumination Power | |
(0022,0057) | FL | 1 | Illumination Bandwidth | |
(0022,0058) | SQ | 1 | Mydriatic Agent Sequence | |
(0022,1007) | SQ | 1 | Ophthalmic Axial Measurements Right Eye Sequence | |
(0022,1008) | SQ | 1 | Ophthalmic Axial Measurements Left Eye Sequence | |
(0022,1010) | CS | 1 | Ophthalmic Axial Length Measurements Type | |
(0022,1019) | FL | 1 | Ophthalmic Axial Length | |
(0022,1024) | SQ | 1 | Lens Status Code Sequence | |
(0022,1025) | SQ | 1 | Vitreous Status Code Sequence | |
(0022,1028) | SQ | 1 | IOL Formula Code Sequence | |
(0022,1029) | LO | 1 | IOL Formula Detail | |
(0022,1033) | FL | 1 | Keratometer Index | |
(0022,1035) | SQ | 1 | Source of Ophthalmic Axial Length Code Sequence | |
(0022,1037) | FL | 1 | Target Refraction | |
(0022,1039) | CS | 1 | Refractive Procedure Occurred | |
(0022,1040) | SQ | 1 | Refractive Surgery Type Code Sequence | |
(0022,1044) | SQ | 1 | Ophthalmic Ultrasound Axial Measurements Type Code Sequence | |
(0022,1050) | SQ | 1 | Ophthalmic Axial Length Measurements Sequence | |
(0022,1053) | FL | 1 | IOL Power | |
(0022,1054) | FL | 1 | Predicted Refractive Error | |
(0022,1059) | FL | 1 | Ophthalmic Axial Length Velocity | |
(0022,1065) | LO | 1 | Lens Status Description | |
(0022,1066) | LO | 1 | Vitreous Status Description | |
(0022,1090) | SQ | 1 | IOL Power Sequence | |
(0022,1092) | SQ | 1 | Lens Constant Sequence | |
(0022,1093) | LO | 1 | IOL Manufacturer | |
(0022,1094) | LO | 1 | Lens Constant Description | |
(0022,1096) | SQ | 1 | Keratometry Measurement Type Code Sequence | |
(0022,1100) | SQ | 1 | Referenced Ophthalmic Axial Measurements Sequence | |
(0022,1101) | SQ | 1 | Ophthalmic Axial Length Measurements Segment Name Code Sequence | |
(0022,1103) | SQ | 1 | Refractive Error Before Refractive Surgery Code Sequence | |
(0022,1121) | FL | 1 | IOL Power For Exact Emmetropia | |
(0022,1122) | FL | 1 | IOL Power For Exact Target Refraction | |
(0022,1125) | SQ | 1 | Anterior Chamber Depth Definition Code Sequence | |
(0022,1130) | FL | 1 | Lens Thickness | |
(0022,1131) | FL | 1 | Anterior Chamber Depth | |
(0022,1132) | SQ | 1 | Source of Lens Thickness Data Code Sequence | |
(0022,1133) | SQ | 1 | Source of Anterior Chamber Depth Data Code Sequence | |
(0022,1135) | SQ | 1 | Source of Refractive Error Data Code Sequence | |
(0022,1140) | CS | 1 | Ophthalmic Axial Length Measurement Modified | |
(0022,1150) | SQ | 1 | Ophthalmic Axial Length Data Source Code Sequence | |
(0022,1153) | SQ | 1 | Ophthalmic Axial Length Acquisition Method Code Sequence | |
(0022,1155) | FL | 1 | Signal to Noise Ratio | |
(0022,1159) | LO | 1 | Ophthalmic Axial Length Data Source Description | |
(0022,1210) | SQ | 1 | Ophthalmic Axial Length Measurements Total Length Sequence | |
(0022,1211) | SQ | 1 | Ophthalmic Axial Length Measurements Segmental Length Sequence | |
(0022,1212) | SQ | 1 | Ophthalmic Axial Length Measurements Length Summation Sequence | |
(0022,1220) | SQ | 1 | Ultrasound Ophthalmic Axial Length Measurements Sequence | |
(0022,1225) | SQ | 1 | Optical Ophthalmic Axial Length Measurements Sequence | |
(0022,1230) | SQ | 1 | Ultrasound Selected Ophthalmic Axial Length Sequence | |
(0022,1250) | SQ | 1 | Ophthalmic Axial Length Selection Method Code Sequence | |
(0022,1255) | SQ | 1 | Optical Selected Ophthalmic Axial Length Sequence | |
(0022,1257) | SQ | 1 | Selected Segmental Ophthalmic Axial Length Sequence | |
(0022,1260) | SQ | 1 | Selected Total Ophthalmic Axial Length Sequence | |
(0022,1262) | SQ | 1 | Ophthalmic Axial Length Quality Metric Sequence | |
(0022,1273) | LO | 1 | Ophthalmic Axial Length Quality Metric Type Description | |
(0022,1300) | SQ | 1 | Intraocular Lens Calculations Right Eye Sequence | |
(0022,1310) | SQ | 1 | Intraocular Lens Calculations Left Eye Sequence | |
(0022,1330) | SQ | 1 | Referenced Ophthalmic Axial Length Measurement QC Image Sequence |